Page 21 - CATALOGO MASCARILLAS QUIRÚRGICAS TIPO IIR
P. 21

Page 12 of 12                                    Report No. 60377885 001

                                                     EN 14683:2019+AC:2019
               Clause     Requirement + Test                               Result - Remark                 Verdict

                                           29                                   Pass                  --
                                           30                                   Pass                  --

                                           31                                   Pass                  --
                                           32                                   Pass                  --
               Supplementary information:
               1, Each specimen was conditioned at   21.0 °C and    81.0   % relative humidity for   4 h to bring them into
               equilibrium with atmosphere prior to testing.
               2, The description of target area tested: the centre of the specimen.
               3, Any technique used to enhance visual detection of synthetic blood:  cotton swab
               4, The temperature and relative humidity for testing:   21.0 °C and   81.0  %
               5, Description of any pre-treatment techniques used: N/A.


               5.2.5      TABLE: Microbial cleanliness (Bioburden)                                          P
               Batch/ lot no.:             Mask(under         Weight of    Total bioburden         Remarks
                                           test) no.:        each mask     per individual
                                                                 (g)            mask
                                                                               (CFU/g)
               20042801                    1                    2.71             <1                   --

                                           2                    2.74             <1                   --
                                           3                    2.77             <1                   --

                                           4                    2.79             <1                   --
                                           5                    2.76             <1                   --
               Supplementary information:





                                                  End of EN 14683 test report



















               QMF-RT-33008SHG                                                   Revision number: 1.0                                                  Effective date: 2020-03-12