Page 13 - Part II:Assessment of conformity
P. 13

Page 13 of 18                     Report No. 20(04)0336P

                                                 EN 149:2001+A1:2009
             Clause     Requirement + Test                             Result - Remark              Verdict


                         The head is arranged to pass over a propane                                   P
                         burner the position of which can be adjusted.
                         By means of a suitable gauge, the distance
                         between the top of the burner, and the lowest
                         part of the facepiece (when positioned directly
                         over the burner) shall be set to (20 ± 2) mm.
                         The test shall be repeated to enable an                                       P
                         assessment to be made of all materials on the
                         exterior of the device. Any one component
                         shall be passed through the flame once only.

             8.7          Carbon dioxide content of the inhalation air                                 P
                          A total of 3 particle filtering half masks shall be  3 samples as received   P
                          tested: all 3 as received.
                         To measure the CO2 content of the inhaled air,                                P
                         5 % of the stroke volume of the inhalation
                         phase of the breathing machine is drawn off at
                         the marked place by an auxiliary lung and fed
                         to a CO2 analyser. The total dead space of the
                         gas path (excluding the breathing machine) of
                         the test installation should not exceed 2000 ml.
                          Measure the carbon dioxide content of the     Less than an average of        P
                          inhaled air and record continuously.          1,0 % (by volume).
                          The test shall be performed until a constant                                 P
                          carbon dioxide content in the inhalation air is
                          achieved.
             8.8         Strength of attachment of exhalation valve     No exhalation valve            N
                         housing
                         A total of three particle filtering half masks                                N
                         shall be tested: one as received, one
                         temperature conditioned in accordance with
                         8.3.2 and one after the test described for
                         mechanical strength in EN 143.

                         Mount the particle filtering half mask securely                               N
                         to a fixture as shown in Figure 9. Apply an
                         axial tensile force of 10 N to the valve
                         (housing) for 10 s, and note the results.
             8.9          Breathing Resistance                                                         P
             8.9.1        Test samples and fixture                                                     P
             8.9.1.1      Valveless particle filtering half masks                                      P

                         A total of 9 valveless particle filtering half                                P
                         masks shall be tested:

                         3 as received, 3 after temperature conditioning                               P
                         in accordance with 8.3.2 and 3 after the test
                         for simulated wearing in accordance with 8.3.1




                                                                                        TRF No. EN 149_1A