Page 15 - CATALOGO MASCARILLAS KN95-FPP2
P. 15
Page 6 of 18 Report No. 20(04)0336P
EN 149:2001+A1:2009
Clause Requirement + Test Result - Remark Verdict
Parts likeyl to come into contact with the wearer N
shall have no sharp edges or burrs
7.9 Leakage P
7.9.1 Total inward leakage P
The laboratory tests shall wearer to protect Enough safe condition is P
with high probability against the potential provide
hazard to be expected.
Exercise results for total inward leakage shall P
be not greater than
25% for FFP1 N
11% for FFP2 FFP2 P
Measured P(%)=6.5%
5% for FFP3 N
7.9.2 Penetration of filter material P
Meet the requirements of Table 1 FFP2 P
Sodium chloride test:
4.5%
7.10 Compatibility with skin P
Materials that may come into contactwith the Have no irritation or adverse P
wearer’s skin shall not be known to be likely to effect to skin and health
cause irritation or any other adverse effect to
health.
7.11 Flammability P
The material used shall not present a danger for P
the wearer and shall not be of highly flammable
nature.
7.12 Carbon dioxide content of the inhalation air N
The carbon dioxide content of the inhalation air <1.0% P
(dead space) shall not exceed an average of 1,0
% (by volume).
7.13 Head harness P
Head harness shall be designed so that mask The design is considered P
can be doned and removed easily.
Head harness shall be adjustable or self- The design is considered P
adjusting and sufficiently robust to hold the
mask firmly in position.
7.14 Field of vision P
The field of vision is acceptable if determined Clear field of vision when P
so in practical performance tests. wearing
7.15 Exhalation valve(s) No exhalation valve N
A particle filtering half mask may have one or N
more exhalation valve(s) and shall function
correctly in all orientations.