Page 11 of 18 Report No. 20(04)0336P
EN 149:2001+A1:2009
Clause Requirement + Test Result - Remark Verdict
A level treadmill is required capable of working at 6 km/h P
6 km/h.
8.5.1.3 Test procedure P
Ask the test subjects to read the P
manufacturer’s fitting information and if more
than one size of particle filtering half mask is
manufactured, ask the test subject to select
the size deemed by him to be the most
appropriate. If necessary the test supervisor
shall show the test subjects how to fit the
particle filtering half mask correctly in
accordance with the fitting information.
Inform the test subjects that if they wish to P
adjust the particle filtering half mask during the
test they may do so. However if this is done,
repeat the relevant section of the test, having
allowed the system to resettle.
The test subjects shall have no indication of the P
results as the test proceeds.
After fitting the particle filtering half mask, ask P
each test subject ‘Does the mask fit?’. If the
answer is ‘Yes’, continue the test. If the answer
is ‘No’, take the test subject off the panel,
report the fact and replace with another test
subject.
The test sequence shall be as follows: P
a) Ensure the test atmosphere is OFF. P
b) Place the test subject in the enclosure. P
Connect up the facepiece sampling probe.
Have the test subject walk at 6 km/h for 2 min.
Measure the test agent concentration inside
the particle filtering half mask to establish the
background level.
c) Obtain a stable reading. P
d) Turn the test atmosphere ON. P
e) The subject shall continue to walk for a further P
2 min or until the test atmosphere has stabilized.
f) Whilst still walking the subject shall perform the P
following exercises:
1) walking for 2 min without head movement or P
talking;
2) turning head from side to side (approx. 15 P
times), as if inspecting the walls of a tunnel for
2 min;
TRF No. EN 149_1A